Elo TouchSystems MonitorMouse FOR WINDOWS NT Version 2.0 Podręcznik Użytkownika Strona 235

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 249
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 234
13
PASS-THRU COMMAND SET (LD9100-PT, LD9100X-PT):
All software commands of the non-pass-thru single sided model are
available with following additional commands for pass-thru and
double-sided display control. When power is turned on or after a
reset command has been initiated, all text is displayed on the pole
display.
Extended Pass-thru Command Set is available as option.
Standard Pass-thru Command Set
1. Data to Peripheral <01>, (01), <^A>:
All data following this command will be sent to the peripheral until
a “Data to Display” command is received.
2. Data to Display <21><23><02>, (33)(35)(02), {!}{#}{^B}:
All data following this command will be sent to the pole display
until a “Data to Peripheral” command is received.
Extended Pass-thru Command Set
1. Data to Peripheral <01><1C><1D><1E>, (01)(28)(29)(30):
All data following this command will be sent to the peripheral until
a “Data to Display” command is received.
2. Data to Display <17><18><19><02>, (23)(24)(25)(02):
All data following this command will be sent to the pole display
until a “Data to Peripheral” command is received.
Przeglądanie stron 234
1 2 ... 230 231 232 233 234 235 236 237 238 239 240 ... 248 249

Komentarze do niniejszej Instrukcji

Brak uwag